Senin, 18 Juni 2012

IR 6570/5570

E000 The heater fails to heat.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0000 After power-on, the reading of the main

thermistor does not increase to 70 deg C or

higher within 20 sec.

- Replace the main/shutter thermistor.

- Replace the DC controller PCB.

0010 The power has been turned off and then on

without resetting the error.

- Reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

    E001 There is an abnormal rise in temperature.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0001 There is an error or an open circuit in the

main thermistor, shutter thermistor, or sub

thermistor.

- Check the connector of each thermistor

for any fault in connection and wiring.

- Replace the thermistor in question.

- Replace the DC controller PCB.

0002 The reading of the main thermistor, shutter

thermistor, or sub thermistor is 230 deg C

or higher for 2 sec.

- Replace the thermistor in question.

- Replace the DC controller PCB.

0003 The reading is not 150 deg C or higher or

210 deg C or lower within 30 sec.

- Turn off and then back on the power.

0010 The power has been turned off and then

back on without resetting the error.

- Reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

E002 There is an abnormal rise in temperature.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0000 The reading of the main thermistor is not

100 deg C 12 sec after it has exceeded 70

deg C.

- Check the connector of the main/shutter

thermistor for any fault in connection and

wiring.

- Check the main/shutter thermistor for

mounting condition.

- Replace the main/shutter thermistor.

- Replace the fixing heater unit.

- Replace the DC controller PCB.

0001 The reading of the main thermistor is not

150 deg C 15 after it has exceeded 100 deg

C.

0010 The power has been turned off and then

back on without resetting the error.

- Reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

    E003 There is an abnormal rise in temperature.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0000 The reading of the main thermistor is

lower than 70 deg C for 2 sec or more after

it has exceeded 100 deg C.

- Check the connector of the main/shutter

thermistor for any fault in connection and

wiring.

- Check the main/shutter thermistor for

mounting condition.

- Replace the main/shutter thermistor.

- Replace the fixing heater unit.

- Replace the DC controller PCB.

0010 The power has been turned off and then

back on without resetting the error.

- Reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

    E004 The IH power supply is faulty/the IH control mechanism is faulty.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0101 There is a mismatch between the input

voltage and the IH power supply ID.

Replace the fixing heater power supply

with one designed for the country of

installation (voltage).

Code Description Remedy

0102 The IH current is faulty. (current leakage) - Check the connector for any fault in

connection.

- Replace the fixing heater power supply.

- Replace the DC controller PCB.

0103 The IH current is faulty. (no current)

0104 There is an IH over-current.

0105 The IH input voltage is too high.

0106 The IH input voltage is too low.

0201 At power-on (or, when IH is at reset), the

IH control mechanism is not in an initial

state.

0202 At IH start-up, the IH control enable flag is

not set within 1 sec after the start flag is

set.

0203 With IH at rest, the IH control flag is not

released.

0204 The 12-V power supply (IH relay) is

identified as being off.

0205 At IH start-up, the PWM_ON data is faulty

('0' or 'FFFF').

- Replace the DC controller PCB.

    E005 There is no fixing web/there is an error in the detection of web solenoid connection.

0000 The absence of the fixing web has been

detected for 5 sec or more.

- Replace the fixing web.

- Replace the fixing web length sensor.

- Replace the DC controller PCB.

After correcting the fault, be user to reset

the fixing web counter reading.

(COPIER>COUNTER>MISC>FIXWEB)

0001 At power-on, the connection of the web

solenoid is not detected.

- Check the connector for any fault in

connection.

- Replace the solenoid.

0010 The power has been turned off and then

back on without resetting the error.

- Reset the fixing web counter.

(COPIER>COUNTER>MISC>FIXWEB)

    E010 There is a feed motor error.

0000 The FG signal of the feed motor does not

arrive for 2 sec or more even when the feed

motor has been turned on.

- Check the connector for any fault in

connection.

- Replace the motor

    E012 There is a drum motor error.

0000 The FG signal of the drum motor does snot

arrive for 2 sec or more even when the

drum motor has been turned on.

- Check the connector for any fault in

connection.

- Replace the motor.

Code Description Remedy

    E013 The waste toner pipe is clogged.

0000 The waste toner pipe is identified as being

clogged for 4 sec or more.

- Check the connector for any fault in

connection.

- Replace the waste toner feedscrew lock

detecting switch.

- Replace the waste toner feed unit.

- Replace the DC controller PCB.

    E014 There is a fixing motor error.

0000 The PULL lock signal of the fixing motor

does not arrive for 2 sec even when the

fixing motor has been turned on.

- Check the connector for any fault in

connection.

- Replace the motor.

    E020 There is no toner in the developing assembly; there is an error in the detection of

developing toner sensor connection; there is an error in the detection of hopper toner

sensor connection

0000 The presence of toner is detected inside the

sub hopper and, in addition, the absence of

toner is detected inside developing

assembly for 120 sec continuously even

when operation has been under way for the

supply of toner to the developing

assembly.

- Check the connector of the developing

toner sensor for any fault in connection.

- Replace the developing toner sensor.

- Replace the hopper toner sensor.

0001 At power-on, the connection of the

developing assembly toner sensor is not

detected.

- Check the connector for any fault in

connection.

- Replace the sensor.

0002 At power-on, the connection of the

developing hopper toner sensor is not

detected.

- Replace the connector for any fault in

connection.

- Replace the sensor.

    E025 There is a toner feed motor over-current detection error, there is a toner bottle motor

connection detection error.

0001 An over-current has been detected in the

toner feed motor.

- Check the connector for any fault in

connection.

- Replace the motor.

0002 An over-current has been detected in the

toner bottle motor.

- Check the connector for any fault in

connection.

- Replace the motor.

0003 At power-on, the connection of the toner

bottle motor is not detected.

- Check the connector for any fault in

connection.

- Replace the motor.

    E032 The NE controller counter has malfunctioned.

Code Description Remedy

0001 An open circuit has been detected for the

count pulse signal.

Turn off the main power, and check for an

open circuit in the cable; then, turn the

main power back on.

    E061 There is a potential control error/there is an APC error.

0001 As a result of potential control, the drum

surface potential (VL2) of the background

is 200 V or higher (i.e., causing a solid

black image).

- Replace the potential sensor unit.

- Replace the laser scanner unit.

- Replace the DC controller PCB.

0002 The primary charging output used at time

of printer output and the drum surface

potential after laser output is identified as

being 200 V or more (i.e., causing a solid

black image).

    E100 There is a BD error.

0001 A check is made of VLOCK at intervals of

100 msec while the laser is on. An error

will be identified if it is not detected 10

times in sequence.

- Replace the laser scanner unit.

- Replace the DC controller PCB.

    E110 There is a polygon motor error.

0001 - Although the polygon motor has been

turned on, VLOCK is not detected at all

within 76.5 sec.

- At time of a shift from full-speed to halfspeed

control, VLOCK is not detected at

all for 7.5 sec.

- At time of half-speed control, a check is

made of VLOCK at intervals of 100 msec.

An error will be identified if it is not

detected 10 times continuously.

- Replace the laser scanner unit.

- Replace the DC controller PCB.

    E121 There is a controller cooling fan error.

0001 Even though the controller cooling fan has

been turned on, the controller cooling fan

stop signal has been detected for 5 sec or

more.

- Check the connector for any fault in

connection.

- Replace the fan.

    E196 The EEPROM is faulty.

Code Description Remedy

1abb There is a mismatch between the data that

has been written in EEPROM and the data

that has been read. (a: chip No. 0 through

5; bb: chip faulty address)

- Initialize the RAM.

- Replace the EEPROM.

- Replace the DC controller PCB.

2abb The ID in EEPROM that has been read and

the ID in ROM are compared. An error

will be identified if they do not match. (a:

chip No. 0 through 5; bb: chip faulty

address)

3abb When the main power is turned on, the ID

in EEPROM and the ID in ROM are

compared. An error will be identified if

they do not match. (a: chip No. 0 through

5; bb: chip faulty address)

- Check the position and condition of the

EEPROM.

- Initialize the RAM.

- Replace the EEPROM.

- Replace the DC controller PCB.

    E202 There is a scanner HP error.

0001 An error has occurred when the sensor was

moved to home position.

The scanner HP sensor is faulty; the

scanner motor is faulty; the reader

controller PCB is faulty.

- Check the connector for any fault in

connection.

- Replace the scanner HP sensor.

- Replace the scanner motor.

- Replace the reader controller PCB.

0002 An error has occurred when the sensor was

moved from home position.

The scanner HP sensor is faulty; the

scanner motor is faulty; the reader

controller PCB is faulty.

    E225 The intensity of light is inadequate.

0001 At time of shading, the intensity if below a

specific level.

- Check the connector for any fault in

connection.

- Replace the scanning lamp.

- Replace the inverter PCB.

- Replace the reader controller PCB.

0002 ADFThe intensity is below a specific level

between sheets (ADF).

    E227 there is an error in the power supply (24 V).

0001 At power-on, the 24-V port is OFF. - Check the connector for any fault in

connection.

- Replace the power supply.

0002 At the start of a job, the 24-V port is OFF.

0003 At the end of a job, the 24-V port is off.

0004 When a load is driven, the 24-V port is

OFF.

E240 The communication between the main controller PCB and the DC controller PCB is

faulty.

Code Description Remedy

0000 There is an error in the communication

between the main controller PCB and the

CPU of the DC controller PCB.

- Check the connector for any fault in

connection.

- Replace the DC controller PCB.

- Replace the main controller PCB.

    E248 There is an EEPROM error.

0001 An error has occurred at power-on. - Replace the EEPROM.

- Replace the reader controller PCB. 0002 An error has occurred at time of write

operation.

0003 An error has occurred at time of read

operation after write operation.

    E315 There is a fault in the image data.

0007 There is a JIBIG encode error. - Turn off and then back on the power.

000d There is a JBIG decode error.

    E400 There is an ADF communication error.

0001 There is a check sum error. - Check the connector for any fault in

connection.

- Replace the reader controller PCB.

- Replace the ADF controller PCB.

0002 There is a reception status error.

0003 There is a reception interrupt error.

    E413 There is a fault in the ADF shift motor.

0001 The output of the shift HP sensor is

identified as indicating open.

- Check the connector for any fault in

connection.

- Replace the sensor and motor in

question.

- Check the mounting condition of the

area around the cam.

0002 The output of the shift HP sensor is

identified as indicating closed.

    E490 The ADF type is wrong.

0001 The ADF is not of a supported type. - Replace the ADF with a supported type.

    E503 There is an error in the finisher internal communication (finisher).

0002 There is an error in the communication

between the finisher and the saddle unit.

- Check the connection between the

saddle stitcher controller PCB and the

finisher controller PCB.

0003 There is an error in the communication

between the finisher and the punch unit.

- Check the communication between the

saddle stitcher controller PCB and the

finisher controller PCB.

    E505 There is a finisher backup memory error (finisher).

Code Description Remedy

0001 An error has occurred in the data stored in

the backup memory.

- Turn off the main power; check the DC

controller PCB and the finisher controller

PCB for wiring; check the 24-V system

fuse; then, turn the main power back on.

0002 There is an error in the punch unit

EEPROM data.

- Turn off the main power; check the DC

controller PCB and the puncher controller

PCB for wiring; then, check the 24-V

system fuse; then, turn the main power

back on.

    E514 There is a trailing edge assist motor error (finisher).

8001 The home position sensor does not go off

even when the trailing edge assist motor

has rotated for a specific period of time.

1. Check the trailing edge assist home

position sensor. Is the sensor normal?

2. Check the wiring between the finisher

controller PCB and the trailing edge assist

motor. Is it normal?

3. Check the trailing edge assist

mechanism. Is there a fault?

4. Try replacing the trailing edge assist

motor. Is the problem corrected?

8002 The home position sensor does not go on

even when the trailing edge assist motor

has rotated for a specific period of time.

    E519 There is a gear change motor error (finisher).

8001 The home position sensor does not go off

even when the gear change motor has

rotated for a specific period of time.

1. Check the gear change home position

sensor. Is the sensor normal?

2. Check the wiring between the finisher

controller PCB and the change motor. Is it

normal?

3. Check the gear change mechanism. Is

there a fault?

4. Try changing the gear change motor. Is

the problem corrected?

0002 The home position sensor does not go on

even when the gear change motor has

rotated for a specific period of time.

    E530 There is a front alignment error. (finisher)

8001 The home position sensor does not go off

even when the front alignment motor has

rotated for a specific period of time.

1. Check the aligning plate home position

sensor. Is it normal?

2. Check the wiring between the finisher

controller PCB and the aligning plate

front motor. Is it normal?

3. Is there any mechanical obstacle in the

path in which the aligning plate moves?

4. Try replacing the aligning plate front

motor. Is the problem corrected?

8002 The home position sensor does not go on

even when the front alignment sensor has

rotated for a specific period of time.

    E531 There is a stapling error. (finisher)

Code Description Remedy

0001 The home position sensor does not go off

even when the stapler motor has rotated for

a specific period of time.

1. Check the wiring between the finisher

controller PCB and the stapler. Is it

normal?

2. Try replacing the stapler. Is the

problem corrected?

0002 The home position sensor does not go on

even when the stapler motor has rotated for

a specific period time.

    E532 There is a stapler shift error. (finisher)

8001 The home position sensor does not go off

even when the stapler shift motor has

rotated for a specific period of time.

1. Check the stapler shift home position

sensor. Is the sensor normal?

2. Check the wiring between the finisher

controller PCB and the stapler shift

motor. Is it normal?

3. Is there any mechanical obstacle in the

path of the stapler shift base?

4. Try replacing the stapler shift motor. Is

the problem corrected?

8002 The home position sensor does not go on

even when the stapler shift motor has

rotated for a specific period of time.

    E535 There is a swing error. (finisher)

8001 The home position sensor does not go off

even when the wiring motor has rotated for

a specific period of time.

1. Check the wiring home position sensor.

Is it normal?

2. Check the wiring between the finisher

controller PCB and the swing motor. Is it

normal?

3. Is there a fault in the swing

mechanism?

4. Try replacing the swing motor. Is the

problem corrected?

8002 The home position sensor does not go on

even when the swing motor has rotated for

a specific period of time.

    E537 There is a rear alignment error. (finisher)

8001 The home position sensor does not go off

even when the swing motor has rotated for

a specific period of time.

1. Check the aligning plate rear home

position sensor. Is it normal?

2. Check the wiring between the finisher

controller PCB and the aligning plate rear

motor. Is it normal?

3. Is there a mechanical obstacle in the

path of the aligning plate?

4. Try replacing the aligning plate rear

motor. Is the problem corrected?

8002 The home position sensor does not go on

even when the swing motor has rotated for

a specific period of time.

    E540 There is an upper tray ascent/decent error. (finisher)

Code Description Remedy

8001 There is a fault in the upper tray ascent/

descent motor clock.

1. Check the No. 1 tray area sensors 1

through 3. Are they normal?

2. Check the wiring between the finisher

controller PCB and the No. 1 tray shift

motor. Is it normal?

3. Is there a fault in the tray ascent/

descent mechanism?

4. Try replacing the No. 1 tray shift

motor. Is the problem corrected?

8002 There is an area fault.

8003 The safety switch has gone on.

    E542 There is a lower tray ascent/descent error. (finisher)

8001 There is a fault in the lower tray ascent/

descent motor clock signal.

1. Check the No. 2 tray area sensors 1

through 3. Are the sensors normal?

2. Check the wiring between the finisher

controller PCB and the No. 2 tray shift

motor. Is it normal?

3. Is there a fault in the tray ascent/

descent mechanism?

4. Try replacing the No. 2 tray shift

motor. Is the problem corrected?

8002 There is an area error.

0003 The safety switch has activated.

    E584 There is a shutter unit error. (finisher)

8001 The shutter open sensor fails to go off.

(The shutter does not close.)

1. Check the shutter home position

sensor. Is it normal?

2. Check the wiring between the finisher

controller PCB and the stack feeding

motor and between the finisher controller

PCB and the shutter open/close clutch. Is

it normal?

3. Is there a fault in the shutter

mechanism?

4. Try replacing the stack edging motor

and the shutter open/close clutch. Is the

problem corrected?

0002 The shutter open sensor does not go on.

(The shutter does not open.)

    E590 There is a punch motor error. (punch unit)

8001 The punch home position sensor is not

detected even when the punch motor has

been driven for 200 msec.

- Check the punch home position sensor,

horizontal registration motor, and punch

driver PCB; thereafter, turn off and then

back on the main power. 8002 The puncher does not detect the punch

home position sensor while the motor is at

rest at time of punch motor initialization.

    E591 There is a punch dust sensor error. (punch unit)

Code Description Remedy

8001 The incoming light voltage is faulty in the

presence of light.

- Turn off and then back on the main

power.

8002 The incoming light voltage is faulty in the

absence of light.

    E592 There is a punch horizontal registration sensor error. (punch unit)

8001 The incoming light voltage is faulty in the

presence of light. (trailing edge sensor)

- turn off and then back on the main

power.

8002 The incoming light is faulty in the absence

of light and voltage. (trailing edge sensor)

8003 The incoming light voltage is faulty in the

presence of light. (horizontal registration

sensor 1)

8004 The incoming light voltage is faulty in the

absence of light. (horizontal registration

sensor 1)

8005 The incoming light voltage is faulty in the

presence of light. (horizontal registration

sensor 2)

8006 The incoming light voltage is faulty in the

absence of light. (horizontal registration

sensor 2)

8007 The incoming light voltage is faulty in the

presence of light. (horizontal registration

sensor 3)

8008 The incoming light voltage is faulty in the

absence of light. (horizontal registration

sensor 3)

8009 The incoming light voltage is faulty in the

presence of light. (horizontal registration

sensor 4)

800A The incoming light voltage is faulty in the

absence of light. (horizontal registration

sensor 4)

    E593 There is a punch shift motor error. (punch unit)

8001 In the presence of light, the incoming light

voltage HP sensor does not go off.

- Turn off and the back on the main

power.

8002 In the absence of light, the incoming light

voltage HP sensor does not go on.

    E5F0 There is a saddle paper positioning error.

Code Description Remedy

0001 The paper positioning plate home position

sensor does not go on even when the paper

positioning plate motor has been driven for

1.33 sec.

paper positioning plate motor (M4S),

paper positioning plate home position

sensor (PI7S)

- Check the paper positioning plate motor

(M4S) and the paper positioning plate

home position sensor (PI7S).

0002 The paper positioning plate home position

sensor does not go off even when the paper

positioning plate motor has been driven for

1 sec.

paper positioning plate motor (M4S),

paper positioning plate home position

sensor (PI7S)

    E5F1 There is a saddle paper folding error.

0001 The number of detection pulses of the

paper folding motor clock sensor is lower

than a specific value.

paper folding motor (M2S), paper folding

motor clock sensor (PI4S)

- Check the paper folding motor (M2S)

and the paper folding motor clock sensor

(PI4S).

0002 The start of the paper folding home

position sensor does not change even when

the paper folding motor has been driven

for 3 sec.

paper folding motor (M2S), paper folding

motor clock sensor (PI4S)

    E5F2 There is a saddle guide error.

0001 The guide home position sensor does not

go on even when the guide motor has been

driven for 0.455 sec.

guide motor (M3S), guide home position

sensor (PI13S)

- Check the guide motor (M3S) and the

guide home position sensor (PI13S).

0002 The guide home position sensor does not

go off even when the guide motor has been

driven for 1 sec.

guide motor (M3S), guide home position

sensor (PI13S)

    E5F3 There is a saddle alignment error.

Code Description Remedy

0001 The aligning plate home position sensor

does not go on even when the aligning

motor has been driven for 0.5 sec. (if at

time of initialization, 1.67 sec)

alignment motor (M5S), aligning plate

home position sensor (PI5S)

- Check the alignment motor (M5S) and

the aligning plate home position sensor

(PI5S).

0002 The aligning plate home position sensor

does not go off even when the aligning

plate has been driven for 1 sec.

alignment motor (M5S), aligning plate

home position sensor (PI5S)

    E5F4 There is a saddle rear stapler error.

0001 The stitching hone position sensor does

not go on even when the stitching motor

(rear) has been driven in reverse for 0.5 sec

or more.

stitching motor (rear, M6S), stitching

home position sensor (rear, MS5S)

- Check the stitching motor (rear, M6S)

and the stitching home position sensor

(rear, MS5S).

0002 the stitching home position sensor does not

go off even when the stitching motor (rear)

has been driven in normal direction for 0.5

sec or more.

stitching motor (rear, M6S), stitching

home position sensor (rear, MS5S)

    E5F5 There is a saddle front stapling error.

0001 The stitching home position sensor does

not go on even when the stitching motor

(front) has been driven in reverse for 0.5

sec or more.

stitching motor (front, M7S), stitching

home position sensor (front, MS7S)

- Check the stitching motor (front, M7S)

and the stitching home position sensor

(front, MS7S).

0002 The stitching home position sensor does

not go off even when the stitching motor

(front) has been driven in normal direction

for 0.5 sec or more.

stitching motor (front, M7S), stitching

home position sensor (front, MS7S)

    E5F6 There is a saddle butting error.

Code Description Remedy

8001 The paper pushing plate home position

sensor does not go on even when the paper

pushing plate motor has been driven for

0.3 sec or more.

paper pushing plate motor (M8S), paper

pushing plate home position sensor

(PI14S)

- Check the paper pushing plate motor

(M8S) and the paper pushing plate home

position sensor (PI14S).

8002 The paper pushing plate home position

sensor does not go off even when the paper

pushing plate motor has been driven for 80

msec.

paper pushing plate motor (M8S), paper

pushing plate home position sensor

(PI14S)

8003 The number of detection pulses of the

paper pushing plate motor clock sensor is

lower than a specific value.

paper pushing plate motor (M8S), paper

pushing plate motor clock sensor (PI1S)

- Check the paper pushing plate motor

(M8S) and the paper pushing plate motor

clock sensor (PI1S).

8004 The paper pushing plate leading edge

sensor does not go off even when the paper

pushing plate motor has been driven for 80

msec.

paper pushing plate motor (M8S), paper

pushing plate leading edge position sensor

(PI15S)

- Check the power pushing plate motor

(M8S) and the paper pushing plate

leading edge position sensor (PI15S).

8005 The paper pushing plate leading edge

position sensor does not go on even when

the paper pushing plate has been driven for

0.3 sec or more.

paper pushing plate motor (M8S), paper

pushing plate leading edge position sensor

(PI15S)

    E5F9 There is a saddle switch error.

Code Description Remedy

0001 With any of the sensor identifying its

respective cover as being closed, the inlet

cover switch is identified as being open for

1 sec from the start of initial rotation or

printing:

- inlet cover sensor (PI9S)

- front cover open/closed sensor (PI2S)

- delivery power sensor (PI3S)

Or, the front cover switch (MS2S) or the

delivery cover switch (MS3S) is open.

inlet cover switch (MS1S), front cover

switch (MS2S), delivery cover switch

(MS3S)

- Check the inlet cover switch (MS1S),

front cover switch (MS2S), and the

delivery cover switch (MS3S).

0002 With any of the following sensors

identifying its respective cover as being

closed, the front cover switch is identified

as being open for 1 sec or more after the

start of initial rotation or printing.

- inlet cover sensor (PI9S)

- front cover open/closed sensor (PI2S)

- delivery cover sensor (PI3S)

- front cover switch (MS2S), delivery

cover switch (MS3S)

- Check the front cover switch (MS2S)

and the delivery cover switch (MS3S).

0003 With any of the following sensors

identifying its respective cover as being

closed, the delivery cover switch is

identified as being open for 1 sec or more

from the start of initial rotation or printing:

- inlet cover sensor (PI9S)

- front cover open/closed sensor (PI2S)

- delivery cover sensor (PI3S)

- delivery cover switch (MS3S)

- Check the delivery cover switch

(MS3S).

    E602 There is a fault on the hard disk.

0001 [Cause] HD detection error: the HD cannot

be detected; the machine fails to turn

ready; an error state is returned.

[Description] at time of Bootrom

processing, BARSAC is started up and

mounted (usrIde).

[Timing] once at power-on

- See details for E602.

Code Description Remedy

0002 [Cause] start-up file absent: the main CPU

program does not exist on the HD (/

BOOTDEV/BOOT/and lower).

[Description] at time of Bootrom

processing, when the system files are

being loaded (usrIde).

[Timing] once at start-up

- See details for E602.

0003 [Cause] HD write abort error: /BOOTDEV

sector on the HD cannot be read.

[Description] BARSAC (all areas at

Bootable start-up)

[Timing] once at start-up

- See details for E602.

0006 [Cause] SubBootable compatible with the

PDL type does not exist in /BOOTDEV/

BOOT.

[Description] when SubBoot in oclibroot

is being loaded

[Timing] once at start-up of Bootable

- See details for E602.

0007 [Cause] ICC-Profile compatible with the

PDL type does not exist in /BOOTDEV/

PDL.

[Description] beginning of oclibroot; the

PDL team function is called and

determined

[Timing] once at start-up of Bootable

- See details for E602.

01XX /DOSDEV is faulty. - See details for E602.

02XX /FSTDEV is faulty. - See details for E602.

03XX /DOSDEV2 is faulty. - See details for E602.

04XX /FSTPDEV is faulty. - See details for E602.

05XX /DOSDEV3 is faulty. - See details for E602.

06XX /PDLDEV is faulty. - See details for E602.

07XX /DOSDEV4 is faulty. - See details for E602.

08XX /BOOTDEV is faulty. - See details for E602.

09XX /DOSDEV5 is faulty. - See details for E602.

FFXX There is an error in a partition that cannot

be identified.

- See details for E602.

    E604 The image memory is faulty or inadequate.

0000 The memory is inadequate for the model. - Add memory.

    E609 The hard disk is faulty.

Code Description Remedy

0008 At time of start-up, the HDD fails to reach

a specific temperature within a specific

period of time.

- Replace the hard disk.

- Replace the DC controller PCB.

0009 At time of a sleep shift, the temperature is

below a specific level.

    E610 The HDD encryption key is faulty. (hardware composition error, initialization error, ID

key error, ID processing error)

0001 There is no encryption board. - Check the hardware composition.

0002 The memory configuration is inadequate

for the use of encryption.

0101 The attempt to initialize the memory used

for storage of the key has failed.

- Turn off and then on the main power.

0102 The attempt to initialize the encryption

processing area has failed.

0201 There is an error in the encryption

processing area.

0202 There is an error in the encryption

processing area.

0301 The attempt to create an ID key has failed.

0302 A fault has been detected in the encryption

key.

- Turn off and then on the main power.

This error will reset all content on the

HDD. 0303 A fault has been detected in the encryption

key.

0401 An error has been detected at time of

coding.

- Turn off and then on the main power.

0402 An error has been detected at time of

decoding.

    E674 There is a fault in the communication between the fax controller PCB (2-line) and the

main controller PCB.

0001 An attempt to set fax device mode has

failed.

- Check the connection of the cable

between the fax controller PCB (2-line)

and the main controller PCB.

- Replace the ROM DIMM of the fax

controller PCB (2-line).

- Replace the fax controller PCB (2-line).

- Replace the main controller PCB.

    E710 There is a fault in IPC initialization.

Code Description Remedy

0001 At time of power-on, the communications

IC on the main controller PCB does not

become ready within 3 sec after start-up.

- Check the connection of the cable.

0002 At time of power-on, the communications

IC on the DC controller PCB cannot be

initialized.

    E711 There is a fault in the IPC communication.

0001 After power-on, the occurrence of an error

has been written 4 times in 1.5 sec to the

error register of the communications IC on

the main controller PCB.

- Check the connection of the cable.

0002 After power-on, a fault has been detected

by the communications IC on the DC

controller PCB.

    E713 There is a fault in the communication with the finisher.

0000 A fault has been detected in the

communications IC on the finisher side.

- Check the connection of the cable.

- Replace the finisher controller PCB.

- Replace the DC controller PCB.

    E717 There is a fault in the communication with the NE controller.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

0001 An error has occurred at time of NE

controller start-up.

The NE controller that was connected

before power-off is not connected at

power-on.

- Check the connection of the cable.

0002 There is an IP error while the NE controller

is in operation.

The IPC may have an open circuit or the

IPC communication cannot be recovered.

    E719 There is a fault in the coin vendor.

After correcting the fault, be sure to reset the error.

(COPIER>FUNCTION>CLEAR>ERR)

Code Description Remedy

0001 An error has occurred at time of coin

vendor start-up.

The coin vendor was connected before

power-off, but is not connected at poweron.

- Check the connector of the cable.

0002 An IPC error has occurred while the coin

vendor is in operation.

The IPC may have an open circuit, or the

IPC communication cannot be removed.

The pickup/delivery signal line has an

open circuit.

An illegal connection has been detected.

0003 While a unit price is being obtained at

start-up, an error has occurred in the

communication with the coin vendor.

0011 An error has occurred at card reader startup.

The card reader that was connected before

power-off is not connected at power-on.

0012 An IPC error has occurred while the card

reader is in operation.

The IPC may have an open circuit, or the

IPC communication cannot be recovered.

    E730 There is a fault in the PDL software.

1001 There is an initialization error. - Execute PDL resetting.

- Turn off and then on the main power. 100A An error has occurred that can be fatal to

the system (e.g., initialization error).

9004 There is a fault in the PAI communication

with an outside controller.

- Turn off and then back on the main

power.

- Check the open I/F board and cable

connection.

- Replace the external controller open I/F

board.

- Replace the main controller PCB.

9005 There is a fault in video connection with an

external controller.

A006 absence of PDL response: there is no PDL

response because of a fault in or the

absence of Subbootable.

- Execute PDL resetting.

- Turn off and then on the main power.

- Check the connection of the SURF

board.

- Re-install the firmware.

- Replace the main controller PCB.

Code Description Remedy

A007 There is a mismatch in version between the

machine control software and the PDL

control software.

- Execute PDL resetting.

- Turn off and then on the main power.

- Execute full formatting and install the

system software.

B013 The font data is corrupted. - Turn off and then on the main power.

- Re-install the system software.

- Execute full formatting and install the

system software.

    E732 There is a fault in the reader communication.

0001 There is a DDI-S communication error. - Check the communication between the

reader unit and the main controller.

- Check the power supply of the reader

unit. (Check to see if initialization takes

place at start-up.)

- Replace the reader controller PCB,

reader relay PCB, or main controller

PCB.

    E733 There is a fault in the printer communication.

0000 The attempt at communication with the

printer fails at start-up.

- Check the connection of the cable

between the DC controller and the main

controller.

- Check the power supply of the printer.

(Check to see if initialization takes place

at start-up.)

- Replace the DC controller PCB or the

main controller PCB.

0001 There is a DDI-P communication error.

    E740 There is a fault in the Ethernet board.

0002 The MAC address is illegal. - Replace the main controller PCB.

    E743 There is a fault in the DDI communication.

0000 An SCI error has occurred; the reception

data is faulty; a reception time-out error

has occurred; a SEQ time-out error has

occurred

- Disconnect and then connect the

connector between the reader unit and the

printer unit.

- Replace the cable, reader controller

PCB, and main controller PCB.

    E744 There is a fault in the language file/boot ROM.

Code Description Remedy

0001 There is a mismatch between the language

version on the HDD and the version of

Bootable.

- Download the language file of the

correct version.

0002 The size of the language file on the HDD

is too big.

0003 There is no language file that is described

in CONfig.txt on the HDD.

0004 A switchover to a language file on the

HDD cannot be made.

1000 The boot ROM in question is one designed

for a different model.

- Replace the boot ROM with one of the

appropriate version.

2000 The engine ID is illegal. - Turn off and then on the main power.

    E745 There is a fault in the TokenRing board.

0001 The attempt to execute PCI initialization

has failed.

- Disconnect and connect the TokeRing

board.

- Replace the TokenRing board.

0002 The MAC address is faulty. - Replace the TokenRing board.

0003 There is an error in the collection/setting of

board information.

0004 There is a connection error. - Check the connection of the cable.

- Replace the cable.

- Check the MAU power supply.

- Replace the MAU.

- Replace the TokenRing board.

0005 An error other than the foregoing has

occurred.

- Turn off and the on the main power.

    E746 There is an error caused by a mismatch of the accessories board.

0003 At start-up, a UFR board for a different

mode has been detected.

- Replace the UFR board with one for the

model in question.

    E748 There is a fault in the combination of the controller board and the DRAM size.

1001 The combination of the main controller

PCB and the SDRAM is wrong.

- Check the correct SDRAM for the

model in question.

    E749 A change has been detected in the product composition.

0000 A change has been made to the product

composition (by PDL type, by MEAP

type).

- Turn off and then on the main power.

This error code is not indicated on the

control panel. It is used in the error

history.

    E804 There is a DC power supply fan error/there is an IH power supply cooling fan error.

Code Description Remedy

0000 The DC power supply fan stop signal has

been detected for 5 sec or more even when

the DC power fan is on.

- Check the connection of the connector.

- Replace the fan.

0001 The IH power supply cooling fan stop

signal has been detected for 5 sec or more

even when the IH power supply cooling

fan is on.

- Check the connection of the connector.

- Replace the fan.

    E805 There is a heat discharge fan error/there is a feed fan error.

0001 The heat discharge fan stop signal has been

detected for 5 sec or more even when the

heat discharge fan is on.

- Check the connection of the connector.

- Replace the fan.

0002 The feed fan stop signal has been detected

for 5 sec even when the feed fan is on.

- Check the connection of the connector.

- Replace the fan.

    E821 There is a cleaner clogging error.

0001 Clogging of toner inside the cleaner has

been detected with reference to an

abnormal rise in the cleaner thermistor.

- Remove the waste toner from inside the

cleaner.

- Replace the air filter of the heat

discharge fan.

    E824 There is a primary charging cooling fan error.

0001 The primary charging cooling fan stop

signal has been detected for 5 sec or more

even when the primary charging cooling

fan is on.

- Check the connection of the connector.

- Replace the fan.

    E840 There is a shutter error.

0001 While the shutter is in operation, the

sensor signal is not detected and, in

addition, it is still not detected after 3

retires.

- Check the connection of the connector

of the shutter motor and the shutter HP

sensor.

- check the mounting of the pin used to

match the shutter gear phase of the fixing

unit (See descriptions under "Points to

Note When Mounting the Fixing Roller.")

- Replace the shutter HP sensor and the

shutter motor.

0002 The interval of ON-OFF detection by the

sensor in response to shutter operation is

shorter than a specific time period.

    E841 There is an error in the detection of fixing inlet guide connection.

0001 At power-on, the connection of the fixing

inlet guide solenoid is not detected.

- Check the connection of the connector.

- Replace the solenoid.
Code Description Remedy